The Fluke 319 is meant to incorporate ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements occurring to 1000 A (319) in tight cable compartments.
The Fluke 319, in addition to paying for AC/DC current measurements and has a well ahead unadulterated for profusion knocked out 40 A. In an optional accessory to a compact package later a sealed feature set, the Fluke 319, in addition, equips subsequent to In-hurry current and Frequency functions for breakdown motors, lighting, etc.
Fluke 319 Clamp Meters are precision instruments designed for accurate AC/DC, voltage, and resistance measurements. Ideal for electricians and industrial professionals, these meters offer true RMS readings and a robust design for reliable performance in demanding environments. Fluke 319 Clamp Meters Price in Bangladesh makes it accessible for both businesses and individual users seeking quality electrical testing tools.
Pico Labs Ltd. provides rental services for Fluke 319 Clamp Meters and other electrical equipment, ensuring cost-effective solutions for short-term projects. With flexible rental plans, technical support, and reliable delivery, Pico Labs Ltd. is your trusted partner for professional electrical tools in Bangladesh.
The two models are economic, compact and offer a range of special features:
| General specifications | |
| Digital display | 6000 count resolution |
| Low battery Indication | Displays a signal when the batteries are below their required voltage |
| Power source | Three AAA IEC LR03 batteries |
| Clamp opening size | 1.45 in (37 mm) |
| Jaw diameter | 1.45 in (37 mm) |
| Dimensions (L x W x H) | 6.39 x 2.29 x 1.20 in |
| (162.4 x 58.25 x 30.5 mm) | |
| Weight | Approximately 13.5 oz (384 g) (batteries included) |
| Auto range | Available in Ohms |
| Safety | CE |
| EN/IEC 61010-1 and IEC 61010-2-032 | |
| Measurement Category: 600V CAT III | |
| 317 Electrical specifications | ||
| Current AC | Range | 40.00 A, 600.0 A |
| Resolution | 0.01 A, 0.1 A | |
| Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
| 2.5% ±8 digit (60-500 Hz) {40 A} | ||
| 1.5% ±5 digit (50-60 Hz) {600 A} | ||
| 2.5% ±5 digit (60-500 Hz) {600 A} | ||
| Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | |
| AC response | rms | |
| Current DC | Range | 40.00 A, 600.0 A |
| Resolution | 0.01 A, 0.1 A | |
| Accuracy | 1.6% ±6 digit (40 A) | |
| 1.5% ±5 digit (600 A) | ||
| Voltage AC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1.5% ±5 digit (20-500Hz) | |
| AC response | rms | |
| Voltage DC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1% ±4 digit | |
| Resistance | Range | 400.0 Ω, 4000 Ω |
| Resolution | 0.1 Ω, 1 Ω | |
| Accuracy | 1% ±5 digit | |
| Continuity | ≤ 30 Ω | |
| Inrush | Integration time | N/A |
| Frequency | Range | N/A |
| Accuracy | N/A | |
| Trigger Level | N/A | |
| 319 Electrical specifications | ||
| Current AC | Range | 40.00 A, 600.0 A, 1000 A |
| Resolution | 0.01 A, 0.1 A, 1 A | |
| Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
| 2.5% ±8 digit (60-500 Hz) {40 A} | ||
| 1.5% ±5 digit (50-60 Hz) {600/1000 A} | ||
| 2.5% ±5 digit (60-500 Hz) {600/1000 A} | ||
| Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A | |
| AC response | rms | |
| Current DC | Range | 40.00 A, 600.0 A, 1000 A |
| Resolution | 0.01 A, 0.1 A, 1 A | |
| Accuracy | 1.6% ±6 digit (40 A) | |
| 1.5% ±5 digit (600/1000 A) | ||
| Voltage AC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1.5% ±5 digit (20-500Hz) | |
| AC response | rms | |
| Voltage DC | Range | 600.0 V |
| Resolution | 0.1 V | |
| Accuracy | 1% ±4 digit | |
| Resistance | Range | 400.0 Ω |
| 4000 Ω | ||
| Resolution | 0.1 Ω | |
| 1 Ω | ||
| Accuracy | 1% ±5 digit | |
| Continuity | ≤ 30 Ω | |
| Inrush | Integration time | 100 ms |
| Frequency | Range | 5.0 - 500.0 Hz |
| Accuracy | 0.5% ±5 digit | |
| Trigger Level | 10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A | |
| The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C) Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. |
||
| Environmental specifications | |
| Operating temperature | 14°F to 122°F (-10 °C to 50 °C) |
| Storage temperature | -40 °F to 140 °F (-40 °C to 60 °C) |
| Operating humidity | Non-condensing (< 50 °F) (< 10 °C) |
| 90% RH (50 °F to 86 °F) (10 °C to 30 °C) | |
| 75% RH (86 °F to 104 °F) (30 °C to 40 °C) | |
| 45% RH (104 °F to 122 °F) (40 °C to 50 °C) | |
| (Without condensation) | |
| Operating altitude | 1 mile (2000 meters) above mean sea level |
| Storage altitude | 7 miles (12,000 meters) above mean sea level |
| IP Rating | IP40 |
| Vibration requirements | Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis |
| Drop test requirements | 3 ft (1 m) drop test, six sides, oak floor |
| EMI, RFI, EMC | Instrument unspecified for use in EMC field ≥ 0.1 V/m |
| Temperature coefficients | 0.1x (specified accuracy)/ °C |
| (<64 °F or > 82° F) | |