Hioki LR8450-01 Memory Hilogger is a high-performance data acquisition system designed for precise voltage, temperature, strain, and vibration measurements. This advanced device offers exceptional flexibility with its modular input units, making it ideal for monitoring and recording multiple parameters in industrial, laboratory, and field environments. Featuring a fast sampling rate of up to 1 MS/s, the Hioki LR8450-01 ensures accurate and reliable data logging for applications in Power & Energy, automotive testing, and production line analysis.
With its wireless LAN connectivity and intuitive touch display, users can easily manage real-time data from remote locations, improving efficiency and workflow. The logger’s compact design, large storage capacity, and compatibility with multiple sensor types make it an essential tool for engineers and technicians who demand high precision and reliability.
If you're looking for the Hioki LR8450-01 Memory Hilogger Price in Bangladesh, Pico Labs Ltd. offers the most competitive pricing and professional after-sales support. Whether you need the device for long-term monitoring or short-term project use, Pico Labs Ltd. provides flexible rental and calibration services to ensure optimal performance and measurement accuracy.
Pico Labs Ltd. delivers trusted calibration and rental solutions for all electrical test and measurement instruments in Bangladesh. Our expert team ensures accuracy, reliability, and cost-effectiveness for industrial, laboratory, and field applications—empowering Power & Energy sectors with world-class equipment and professional technical support.
Accuracy guaranteed: 1 year
| Max. number of connectable modules | 4 plug-in modules + 7 wireless modules | |||||
|---|---|---|---|---|---|---|
| Connectable modules (Plug-in modules) |
See [Options] > [Plug-in modules] | |||||
| Connectable modules (Wireless modules) |
See [Options] > [Wireless modules] | |||||
| No. of measurement channels | Up to 120 ch with plug-in modules, up to 330 ch with plug-in modules and wireless modules (U8555 and LR8535 can input up to 500 channels per module) |
|||||
| Pulse/logic input | [Number of ch] 8 ch (common GND, non-isolated, exclusive setting for pulse/logic input for individual channels) [Adaptive input format] Non-voltage contact, open collector, or voltage input [Count] 0 to 1000 M pulse, 1 pulse resolution [Rotational speed] 0 to 5000/n (r/s), 1/n (r/s) resolution, 0 to 300,000/n (r/min.), 1/n (r/min.) resolution, n: Number of pulses per rotation (1 to 1000) [Logic input] Records 1 or 0 for each recording interval |
|||||
| Recording intervals | 1 ms*, 2 ms*, 5 ms* (*: Can be set only when using 1 ms/S modules), 10 ms to 1 hour, 22 selections (Data refresh interval can be set for each module) | |||||
| Data storage | SD Memory Card/USB Drive (user-selectable) (Only storage media sold by HIOKI are guaranteed for operation) |
|||||
| LAN interface | 100BASE-TX / 1000BASE-T, DHCP, DNS support, Functions: Data acquisition, condition settings used with the Logger Utility software, configuring settings and controlling recording using communications commands, FTP server / FTP client, HTTP server, Email transmission, NTP client |
|||||
| Wireless LAN interface | IEEE 802.11b/g/n Communications range: 30 m, line of sight Encryption function: WPA-PSK/WPA2-PSK, TKIP/AES Usable channels: 1 to 11 Supported modes: Wireless module connectivity, access point, station Functions: Configuring settings and controlling recording using communications commands, FTP server / client, HTTP server, Email transmission, NTP client |
|||||
| USB interface | Series A receptacle × 2: USB 2.0 compliant (USB drive, keyboard, or hub)) Series mini-B receptacle × 1: Data acquisition, condition settings used with the Logger Utility, configuring settings and controlling recording using communications commands, transferring data from a connected SD Memory Card to a computer |
|||||
| SD card slot | SD standard-compliant slot × 1 (with SD memory card/SDHC memory card support), Guaranteed-operation options: Z4001, Z4003 | |||||
| Display | 7 inch TFT color liquid crystal display (WVGA 800 × 480 pixel) | |||||
| Functions | Save waveform data in real time to the SD memory card or USB drive, numerical value calculations, waveform calculations, 8ch alarm output, voltage output ×2 (5 V /12 V /24 V selectable) | |||||
| Power supply | [AC adapter] Using the Z1014 (100 to 240 V AC, 50/60 Hz), 95 VA Max. (including AC adapter), 28 VA Max. (exclusive of AC adapter) [Battery Pack] Using the Z1007 (accommodates 2 batteries), continuous use 4 hr (reference value for 2 pieces), 20 VA Max. [External power] 10 to 30 V DC, 28 VA Max. |
|||||
| Dimensions and mass | Without any modules: 272 mm (10.71 in) W × 145 mm (5.71 in) H × 43 mm (1.69 in) D (excluding protrusions), 1108 g (39.1 oz) (excluding battery pack) With 2 modules: 272 mm (10.71 in) W × 198 mm (7.80 in) H × 63 mm (2.48 in) D (excluding protrusions) With 4 modules: 272 mm (10.71 in) W × 252 mm (9.92 in) H × 63 mm (2.48 in) D (excluding protrusions) |
|||||
| Included accessories | Quick Start Manual ×1, LOGGER Application Disc (Quick Start Manual, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, CAN editor, CAN editor instruction manual, Communication Instruction Manual) ×1, USB Cable ×1, AC Adapter Z1014 ×1, Precautions Concerning Use of Equipment that Emits Radio Waves ×1 | |||||
Last update: March 2025
| Countries and regions where wireless operation is currently supported | Austria, Belgium, Bulgaria, Canada, China, Colombia, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Georgia, Germany, Greece, Hong Kong, Hungary, Iceland, India, Indonesia, Ireland, Israel(*1), Italy, Japan, Kenya, Korea, Latvia, Liechtenstein, Lithuania, Luxembourg, Macao, Malta, Myanmar, Netherlands, New Caledonia, Norway, Poland, Portugal, Romania, Saudi Arabia, Singapore, Slovakia, Slovenia, Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, United Kingdom, United States, Viet Nam *1: The approval is valid for specific distributor or importer only. Please be consulted by our sales office for details. |
|||||
|---|---|---|---|---|---|---|
| Note | Use of devices that emit radio radiation requires approval in the country of use. Thus, use of the instrument in a country or region where they have not been approved may be subject to penalty as a violation of law. | |||||