Get Support

+8801977426642

Fluke 154 HART Communicator

  • Home
  • Fluke 154 HART Communicator

Fluke 154 HART Communicator

"HART Calibration manage to pay for advice at your fingertips"

Combine moreover a Fluke calibrator for a quantity HART calibration resolved.

The Fluke 154 is a standalone tablet based HART communication tool. The tablet configured taking into account the "FlukeHART" mobile app utilizes a wireless HART modem that connects directly to the HART transmitter stir thing tested or configured. When you adding together occurring your Fluke 154 Communicator behind a Fluke 750 Series Documenting Process Calibrator, or a 720 Series Multifunction Process Calibrator you have a utter HART calibration and configuration genuine.

The 154 puts HART device configuration at your fingertips. An Android based tablet fan interface makes HART configuration easy. The outside wireless modem allows you to member up the modem to the transmitter swine tested consequently you can communicate to the device remotely. HART transmitters can often be found in confined spaces that are hard to admission, or are out of make a make a get of of. The Fluke 154 helps admittance the exaggeration to stand right against the device being tested or configured thus you can ham it taking place from a safer, more convenient location.

Multiple language maintain: Select language from the Android dynamic system. Hart communication commands are limited to English per the HART device descriptions.

Wireless HART Modem: Includes configurable relationship cable that accepts either the hook clips for connecting to wires or the elongated tooth alligator clips expected to secure to transmitter membership screw heads. Rechargeable lithium-ion battery lasts easily for several days of HART device configuration and psychiatry comings and goings. Rugged enclosure and exam gain set designed for process environments.

Key Features: Fluke 154 HART Communicator

  • Full HART Device Description (DD) support of all HART devices
  • Configure HART devices
  • Perform HART trim on HART devices when used with a Fluke 750 or 720 series calibrator
  • Monitor device PV, SV, TV, QV and other measured HART variables
  • Convenient wireless connectivity to HART modem
  • Easy to use, fast connect and view HART data
  • Store HART device configurations
  • Long range wireless communication up to 250 feet

Specifications: Fluke 154 HART Communicator

Tablet
Operating system Android 5.0 or newer
Processor ARM or Atom
Memory RAM 1 GB
Memory ROM 2 GB
Screen 960x540 qHD
Communication port Bluetooth
HART Modem
Enclosure
Material High strength ABS Plastic
Dimensions 10.16 x 2.5 x 6.9 cm (4 x 1 x 2.75 in)
Total unit weight 0.16 kg (0.36 lbs)
Cables
HART cable length 4 ft (1.2 m)
HART cable connectors Mini-Grabber
HART Interface
Interface Capacitive coupling
Output 600 mVpp
Leakage < 10 uA
Connections Across loop resistor or HART field device
Specifications HART 4, HART 5, HART 6, HART 7
HART physical layer spec HCF_SPEC-54
Bluetooth
Specification Bluetooth v2.0
Frequency 2.4 GHz
Class 1 master distance 275 ft (83.8 m)
Battery
Type Rechargeable Li-Ion
Life 19 hours continuous use
Environmental
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -10 °C to 45 °C (-14 °F to 113 °F)
Humidity 0% to 90% (non-condensing)

Customer Reviews


Add a Review

Your Ratings: