A pressure range 100 grow early smaller than the full scale will meet the run specifications without reducing supply pressure. For example, an 8370A subsequently a 70 MPa (10 000 psi) high range module and a 700 kPa (100 psi) low range module will be skillful to manage pressures knocked out 700 kPa (100 psi) to within 0.014 kPa (0.002 psi) without reducing the supply pressure.
Flexible configuration options of Fluke modular tall-pressure calibrators
The 8270A and 8370A are modular systems that can be configured considering going on to five measurement modules at the similar period, in view of that they can handle high pressure, low pressure, and anything in along as well as. Three families of modules offer three levels of action that consent to you set occurring a system matching your needs for correctness and value.
So, surely you can now depend upon the rugged and honorable Fluke Modular High-Pressure Calibrators that always find the maintenance for the value. Quick make a get of now from Tools Bangladesh.
| General specifications | |
| Mains | |
| Power requirements | 100 V ac to 240 V ac, 47 Hz to 63 Hz |
| Fuse | T3.15 A 250 V ac |
| Max power consumption | 100 W |
| Environment | |
| Operating ambient temperature range | 15 °C to 35 °C |
| Storage temperature | -20 °C to 70 °C |
| Relative humidity | Operating: <80 % to 30 °C, <70 % to 40 °C |
| Storage: <95 %, non-condensing. A power stabilization period of four days may be required after extended storage at high temperature and humidity. | |
| Vibration | MIL-T-28800E |
| Altitude (operation) | <3000 m |
| Warm up time | 15 minutes after power up or module installation, when items previously stored within Operating Ambient Temperature Range. |
| Compliance | |
| Ingress protection | IEC 60529:IP20 |
| Safety | IEC 61010-1, Installation Category II, Pollution degree 2 |
| Weight and Dimensions | |
| Weight (Chassis only) | 13 kg (28.5 lbs) / 15 kg (35.25 lbs) |
| Dimensions | Height: 147 mm (5.78 in) |
| Width: 452 mm (17.79 in) | |
| Depth 488 mm (19.2 in) | |
| Rack mount dimensions | 3U-19 inch rack |
| Electromagnetic Compatibility (EMC) | |
| IEC 61326-1 (Controlled EM environment | IEC 61326-2-1; CIPR 11: Group 1, Class A Group 1 equipment has intentionally generated and/or uses conductivity coupled radio-frequency energy which is necessary for the internal functioning of the equipment itself.
Class A equipment is equipment suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Emissions which exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of 61326-1 when test leads and/or test probes are connected. |
| USA (FCC) | 47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103. |
| Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. |
| Communication Interfaces | |
| Primary Remote Interfaces | IEEE, Ethernet, RS-232, USB |
| System Connection | Supports interconnection of 2 or 3 systems |
| Switch Test Connection | Standard BNC Jack: Nominal 24 V dc isolated drive Maximum 30 V dc w.r.t.chassis ground |
| Aux Drivers | 4 external Solenoid Drivers 24 V dc Drive (Maximum drive 6 W continuous per channel |
| Operating characteristics | ||||||||||||||||||||||||||||||
| Control specifications | ||||||||||||||||||||||||||||||
| 95 % of setpoints are within specification limits for stated conditions as calculated by mean plus 1.67 standard deviations of test data. | ||||||||||||||||||||||||||||||
| Control Precision (Dynamic Mode) | 0.002% Range Span or 0.01 kPa (whichever is greater) | |||||||||||||||||||||||||||||
| Control Turndown | 100:1 (typical)
To meet the control specifications, supply pressure should not be greater than 100 times the range of the measurement module. Control turndown is defined as the relationship between the provided supply pressure and the appropriate supply pressure for the range |
|||||||||||||||||||||||||||||
| Low Control Point | 1 kPa (0.15 psi) absolute (8270A only) 7 kPa (1.0 psi) gauge (8370A, 8270A without vacuum pump) |
|||||||||||||||||||||||||||||
| Settling Time | Settling time is the time required to be within 0.005% of setpoint for 10 % steps into volumes up to 50 cm3 for all pressures >7 kPa absolute (8270A) or 7 kPa gauge (8370A). Settling time may be affected by multiple variables, including temperature effects, component flow rates, leaks, and overall volume configurations.
|
|||||||||||||||||||||||||||||
| Overshoot (Dynamic A) | 0.08% Full Scale or 2 kPa (whichever is greater) | |||||||||||||||||||||||||||||